Show detailed connections and sequences.Show processes broken down into steps and use symbols that are easy to follow.Identify problems and possible solutions.Help with problem solving and decision making. Provide effective visual communication of ideas, information and data.Process maps can save time and simplify projects because they: Improve communication between individuals engaged in the same process.Analyze how a process could be improved.Process mapping allows you to visually communicate the important details of a process rather than writing extensive directions. +/-0.Process mapping spotlights waste, streamlines work processes and builds understanding. Susceptibility to electromagnetic fields - test level: 30 V/m (1.4 GHz.2 GHz) conforming to EN/IEC 6 Susceptibility to electromagnetic fields - test level: 10 V/m (80.1000 MHz) conforming to EN/IEC 6 Muting function of light curtains conforming to EN/IEC 6Ĭomplementary Synchronisation time between inputsĢ50 V AC between power supply and housing conforming to EN/IEC 6Įlectrostatic discharge immunity test - test level: 6 kV (on contact) conforming to EN/IEC 6Įlectrostatic discharge immunity test - test level: 20 kV (on air) conforming to EN/IEC 6 Safety mat monitoring conforming to EN/ISO 14119Įnabling switch monitoring conforming to EN 61326-1 Magnetic switch monitoring conforming to EN/ISO 14119 Light curtain monitoring conforming to EN/IEC 61496-1įoot switch monitoring conforming to EN/IEC 6 Guard monitoring conforming to EN/ISO 14119Įnabling switch monitoring conforming to EN/IEC 6 Modicon MCM modular safety controller system are designed to monitor multiple safety functions on and around a machine to minimise the risk of people accessing the dangerous moving parts of the machine.Ģ digital for interlock start/restart or external device monitoringĢ safety outputs OSSD for contactor/drive connectionĮmergency stop conforming to EN/ISO 13850 The Modicon MCM modular safety controller system provide flexibility and scalability from 8 inputs, 2 dual/4 single channel outputs up to 128 inputs, 16 dual/32 single channel outputs, up to 32 or 48 diagnostic status outputs. The safety controller CPU instals on Omega 35mm DIN rail conforming to EN 50022. Compatible accessories for Modicon MCM module are a memory card and the backplane connector. The safe controller CPU Modicon MCM are certified by TüV SÜD meeting the industrial safety standards of Category 4, PL e according to EN/ISO 13849-1 and SILCL 3 according to IEC/EN 61508 and IEC/EN 60261. It is ideal for monitoring safety functions such as emergency stop, guard monitoring, perimeter guarding, position monitoring, speed monitoring and enabling movement. Its dimension are 22.5mm (Depth), 99mm (Height) and 114.5mm (Width). It is furnished with spring clamp terminals, removable terminal block for electrical connection. It is a CPU with a rated supply voltage of 24V DC and a maximum power dissipation of 3W. This safety controller CPU figures LEDs on its front face, displaying the status (power supply, run, internal or external errors, inputs status, communication, master enable, restart signal, output channels). The system is expandable up to 128 inputs, 16 outputs and up to 32 diagnostic status outputs, ideal for machines requiring multiple safety function monitoring. It can be used as standalone or with fourteen expansion modules. It is an appropriate solution for machines with a small number of safety functions requiring the configuration flexibility of a safety controller. It embeds a Mini USB 2.0 connector to receive the configuration done with the software EcoStruxure Machine Expert - HVAC. This Modicon MCM safety controller CPU is supplied with 24Vdc, has 8 safe digital inputs, 2 start/restart interlock inputs, 2 output OSSD pairs, 4 test outputs and 2 status outputs and is fitted with captive screw clamp terminals.
0 Comments
Leave a Reply. |